Bolier
sampling system |
Hydrazine
analyzer |
Sodium
ion monitor |
|
|
|
HDIC-4 |
HYM-300 |
EMNA-10 |
lEnable pH control of pure & ultra pure water
lTemperature compensation by
RTD (platinum)
lRepeatability of ±0.03pH,±1digit
lScaling function enables response to slight changes
l2 points automatic calibration function
lElectrode performance test & self diagnosis functions available
lDisplay switchable between temperature & pH
lMeas.range:pH 0.00~14.00,0.00~ 99.9℃ |
lContinuous measurement of hydrazine concentration in boiler water
lStabilization determination function during calibration
lBest suited for monitoring of residual hydrazine concentration which eliminates dissolved
oxygen within boiler water
lMeas.range:0~999.9ug/L |
lContinuously measures Naion concentration of ppb order within boiler water
lMonitors degradation of ion-exchange system
lMeas.range:0~0.1/1~100/10~1000ppb(manually switched)
|
|
|
|
Continunous
silica analyzer |
Auto
calibration pH meter |
Conductivity/resistivity
meter |
|
|
|
CDIC-1 |
DODI-1 |
DHDI-1 |
lReliable measurement attainable for pure & ultra pure water
lTemperature compensation by
RTD (platinum)
lEquipped with 2 input channels thus 2 points sample measurement possible
lWide measurement range
lAlternates display of
conductivity, receptivity & temperature
lMeas.range:0.00~20.00us/cm or MΩ/cmF.S.(3 ranges),0.00~99.9℃ |
lResponsive to wide range of needs from general use to
nuclear power station
lDirectly reads off DOlevel of ug/L order
lHighly responsive to rapid changes
lEase of calibration attained with ambient calibration method
lMeasurable with closed loop
lEquipped with automatic range function
lAlternates display of ug/L,mg/L & %
lMeas.range:0.0~20.00mg/L0~250% F.S.(4 ranges)
|
lMonitors high temperature oxide corrosion of material by ultra supercritical pressure
lAlternates display of ug/L,mg/L & %
lEase of calibration attained by ambient calibration method
lHighly responsive to rapid changes
lMeasurable with closed loop
lEquipped with automatic range function
lMeas.range:0.0~20.00mg/L 0~200% F.S.(4 ranges)
|
|
|
|
Dissolved
oxygenmeter |
Dissolved
hydrogen meter |
|
|
|
|
BSC |
SLF-103 |
|
lCooler,
pressure reducer, valves, flow meter & thermostat chamber all built into one unit
lExtraction of sample for analysis from boiler
lWe manufacture whole system from analyzer to sampler
lSample condition: Maximum temperature:600℃,maximum pressure:30MPa ,maximum flou rate:3L/min
|
lMeasures concentration of ionic state silica within water
lContinuous flow analysis method by Molybdenum blue absorptiometry used
lWall mounting
lSingle or 6 flow paths selectable
lMeas.range:0~50/0~500ug/L |
|
|
|
|